Fibre Optic Ducting & Raceway Systems for Data Centres

Fibre optic ducting (also called fibre raceway or fibre trunking) is an enclosed, overhead or under-floor channel used only for fibre patch cords and jumpers. It keeps fibre separate from copper and power cabling, stops it being crushed or snagged, and makes sure every turn keeps to the cable's minimum bend radius. The bright yellow colour marks the route as fibre-only, so other trades keep their cables out.

Our 160 × 100 mm yellow fibre ducting system is made up of 2-metre straight lengths with clip-on covers and a full set of matching fittings. These are 45° and 90° horizontal elbows, 90° up elbows, 45° and 90° down elbows, tees and crosses. With these parts you can route fibre from the meet-me room to every row, along the cabinet line and down into the racks.

Which fitting do I need?

Fitting What it does
Main duct + cover (2 m) Straight runs along the row or between rooms
Horizontal elbow 90° / 45° Changes direction on the same level, e.g. at the end of a row
Up elbow 90° Turns the route upwards, e.g. to rise over an obstruction or to a higher tier
Down elbow 90° / 45° Turns the route downwards towards cabinets, frames or a lower level
Tee Branches one route into two, e.g. from a spine into a row
Cross A four-way junction where two routes intersect

Every fitting is sold as a body with a separate matching cover, so remember to order both.

How to size fibre ducting

Plan for growth. A good rule is to fill the duct to no more than 50% on day one, which leaves room for future patch cords without crushing the cables at the bottom. Choose fittings rather than bending the duct on site: the curved fittings are what keep the fibre inside its minimum bend radius. Most standard and bend-insensitive patch cords are rated for a minimum radius of around 30 mm. Read our fibre raceway design guide for capacity estimates, layout tips and a full checklist.

Related data centre cable management

Fibre ducting is one part of a data centre cable management strategy. You may also need data centre microducts and textile sub-tubing for blown fibre, cable trunking and trays for copper and power, and fibre patch cords, fibre patch panels and ODFs at each end. Our guide to data centre cable management explains how they fit together. To plan a full fibre route, contact our technical team.